S3700-52P-EI-48S-AC

S3700-52P-EI-48S-AC
[Contactaţi-ne pentru preţ]
Întreabă stoc

Specification (S3700-52P-EI-48S-AC)

ItemS3700-SI*S3700-EI*
Ports descriptionS3700-28TP-EI**/S3700-28TP-SI/S3700-28TP-PWR-SI/S3700-28TP-PWR-EI/S3700-28TP-EI-MC: 24*10/100Base-TX
S3700-52P-EI/S3700-52P-SI/S3700-52P-PWR-EI/S3700-52P-PWR-SI: 48*10/100Base-T
S3700-28TP-EI-24S: 24*100Base-FX
S3700-52P-EI-24S: 24*10/100Base-T+24*100Base-FX
S3700-52P-EI-48S: 48*100Base-FX
SI/EI 28 ports: 2*1000Base-X, 2*GE Combo
SI/EI 52 ports: 2*100/1000Base-X, 2*1000Base-X
MAC address tableIEEE 802.1d compliance
16K MAC address entries
MAC address learning and aging
Static, dynamic, and blackhole MAC address entries
Packet filtering based on source MAC addresses
VLAN4K VLANs
Guest VLANs, voice VLAN, and super VLAN
MUX VLAN and GVRP
VLAN assignment based on MAC addresses, protocols, and IP subnets
QinQ
Selective QinQ
1:1 VLAN mapping
N:1 VLAN mapping
ReliabilityRRPP (ring topology, intersecting rings, and multi-instance), implementing protection switchover within 50 ms
Smart Link tree topology and Smart Link multi-instance, providing the millisecond-level protection switchover
STP(IEEE 802.1d), RSTP(IEEE 802.1w), and MSTP(IEEE 802.1s)
BPDU protection, root protection, and loop protection
Smart Ethernet Protection (SEP)
N/ABFD for OSPF, BFD for IS-IS, BFD for VRRP, and BFD for PIM
IP routingStatic routing, RIPv1, RIPv2, and ECMP
N/AOSPF, IS-IS, and BGP
IPv6 featuresNeighbor Discovery (ND)
Path MTU (PMTU)
IPv6 ping, IPv6 tracert, and IPv6 Telnet
Manually configured tunnel
6to4 tunnel
ISATAP tunnel
ACLs based on the source IPv6 address, destination IPv6 address, Layer 4 ports, or protocol type
MLD v1/v2 snooping
Multicast1 K multicast groups
IGMP v1/v2/v3 snooping and IGMP fast leave
Multicast VLAN and multicast replication between VLANs
Multicast load balancing among member ports of a trunk
Controllable multicast
Port-based multicast traffic statistics
N/AIGMP v1/v2/v3, PIM-SM, PIM-DM and PIM-SSM
QoS/ACLRate limiting on packets sent and received by an interface
Packet redirection
Port-based traffic policing and two-rate three-color CAR
Eight queues on each port
WRR, DRR, SP, WRR+SP, and DRR+SP queue scheduling algorithms
Re-marking of the 802.1p priority and DSCP priority
Packet filtering on Layers 2 through 4, filtering out invalid frames based on the source MAC address, destination MAC address, source IP address, destination IP address, port number, protocol type, and VLAN ID
Rate limiting in each queue and traffic shaping on ports
SecurityUser privilege management and password protection
DoS attack defense, ARP attack defense, and ICMP attack defense
Binding of the IP address, MAC address, interface, and VLAN
Port isolation, port security, and sticky MAC
Blackhole MAC address entries
Limit on the number of learned MAC addresses
802.1x authentication and limit on the number of users on an interface
AAA authentication, RADIUS authentication, HWTACACS authentication, and NAC
SSH v2.0
CPU defense
Blacklist and whitelist
Surge protection6KV surge protection capability on service ports (1KV on service ports on PoE devices)
Management and maintenanceiStack
MAC Forced Forwarding (MFF)
Remote configuration and maintenance using Telnet
Auto-Config
Virtual cable test
Ethernet OAM (IEEE 802.3ah and 802.1ag)
Dying gasp power-off alarm (S3700-28TP-EI-MC-AC)
SNMP v1/v2c/v3 and RMON
Web NMS
Operating environmentOperating temperature: 0℃–50℃(long term);
Relative humidity: 10%–90% (non-condensing)
Power supplyAC:
Rated voltage range: 100V to 240V AC; 50/60 Hz
Maximum voltage range: 90V to 264V AC; 50/60 Hz
DC:
Rated voltage range: –48V to –60V DC
Maximum voltage range: –36V to –72V DC
Note: PoE-support switches do not use DC power supplies.
Dimensions (W x D x H)S3700-28TP-EI/SI, S3700-28TP-EI-MC, S3700-28TP-EI-24S, S3700-52P-EI/SI: 442 mm x 220 mm x 43.6 mm
S3700-28TP-PWR-EI/SI, S3700-52P-EI-48S, S3700-52P-EI-24S, S3700-52P-PWR-EI/SI: 442 mm x 420 mm x 43.6 mm
WeightS3700-28TP-SI<2.5Kg
S3700-52P-SI<3Kg
S3700-28TP-PWR-SI<4Kg
(without power supply)
S3700-52P-PWR-SI<4.3Kg
(without power supply)
S3700-28TP-EI<2.5Kg
S3700-28TP-EI-MC<2.5Kg
S3700-28TP-EI-24S<2.6Kg
S3700-52P-EI<3Kg
S3700-52P-EI-24S<4.8Kg
S3700-52P-EI-48S<4.8Kg
S3700-28TP-PWR-EI<4Kg
(without power supply)
S3700-52P-PWR-EI< 4.3Kg
(without power supply)
Power consumptionS3700-28TP-SI<20W
S3700-52P-SI<38W
S3700-28TP-PWR-SI<818W
(PoE: 740W)
S3700-52P-PWR-SI<880W
(PoE: 740W)
S3700-28TP-EI<20W
S3700-28TP-EI-MC<20W
S3700-28TP-EI-24S<52W
S3700-52P-EI<38W
S3700-52P-EI-24S<65W
S3700-52P-EI-48S<90W
S3700-28TP-PWR-EI<818W
(PoE: 740W)
S3700-52P-PWR-EI<880W
(PoE: 740W)

Nu au fost găsite recenzii

Possibly you may be interested
  • Most Popular
  • Bestsellers
  • Recently Viewed
 
 
 
Fast and high quality delivery

Our company makes delivery all over the country

Quality assurance and service

We offer only those goods, in which quality we are sure

Returns within 30 days

You have 30 days to test your purchase